Abstract

An electrical capacitance tomography (ECT) sensor consists of a number of electrodes, which are usually mounted around the external or internal periphery of a circular insulated pipe. Therefore, the diameter of a conventional ECT sensor is fixed. This paper presents a new structure of ECT sensor, which can achieve adjustable inner diameter of the sensor within a certain range, by re-engineering the traditional structure, and therefore the electrode-to-gap ratio (EGR) of the sensor is changed. The relationship between EGR and image quality was studied by simulation. A prototype ECT sensor with variable diameter was fabricated and evaluated with an impedance-analyzer based ECT system. The experimental results show that the ECT sensor with variable diameter can provide similar reconstructed images to a conventional ECT sensor, when the sensor diameter varies in a certain range, i.e. EGR above 6:1. Therefore, this new structure can enable the ECT sensor to be adapted to the change in diameter of the measured objects.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call