Abstract

View-sharing (VS) increases spatiotemporal resolution in dynamic contrast-enhanced (DCE) MRI by sharing high-frequency k-space data across temporal phases. This temporal sharing results in respiratory motion within any phase to propagate artifacts across all shared phases. Compressed sensing (CS) eliminates the need for VS by recovering missing k-space data from pseudorandom undersampling, reducing temporal blurring while maintaining spatial resolution. To evaluate a CS reconstruction algorithm on undersampled DCE-MRI data for image quality and hepatocellular carcinoma (HCC) detection. Retrospective. Fifty consecutive patients undergoing MRI for HCC screening (29 males, 21 females, 52-72 years). 3.0T MRI. Multiphase 3D-SPGR T1 -weighted sequence undersampled in arterial phases with a complementary Poisson disc sampling pattern reconstructed with VS and CS algorithms. VS and CS reconstructions evaluated by blinded assessments of image quality and anatomic delineation on Likert scales (1-4 and 1-5, respectively), and HCC detection by OPTN/UNOS criteria including a diagnostic confidence score (1-5). Blinded side-by-side reconstruction comparisons for lesion depiction and overall series preference (-3-3). Two-tailed Wilcoxon signed rank tests for paired nonparametric analyses with Bonferroni-Holm multiple-comparison corrections. McNemar's test for differences in lesion detection frequency and transplantation eligibility. CS compared with VS demonstrated significantly improved contrast (mean 3.6 vs. 2.9, P < 0.0001) and less motion artifact (mean 3.6 vs. 3.2, P = 0.006). CS compared with VS demonstrated significantly improved delineations of liver margin (mean 4.5 vs. 3.8, P = 0.0002), portal veins (mean 4.5 vs. 3.7, P < 0.0001), and hepatic veins (mean 4.6 vs. 3.5, P < 0.0001), but significantly decreased delineation of hepatic arteries (mean 3.2 vs. 3.7, P = 0.004). No significant differences were seen in the other assessments. Applying a CS reconstruction to data acquired for a VS reconstruction significantly reduces motion artifacts in a clinical DCE protocol for HCC screening. 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:984-993.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.