Abstract
A model describing a dynamic system subjected to repetitive impulse was developed. The methodology presented addressed the specific case where the impulse repetition occurred at equal time intervals. The methodology was illustrated through an example, where a cryocooler induced repetitive impulse to a cryocooler cooled device. The analysis considered both a rigidly and a flexibly mounted cryocooler. Passive control was implemented by varying the coupling stiffness between the cryocooler and the cryocooler cooled device, the cryocooler stiffness to ground and the mass of the cryocooler. The selected objective functions that were minimized, were functions of the displacement and velocity of the cryocooler cooled device.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.