In this paper simulation and experimental results of Strain rate feedback for active vibration control of a cantilever beam are presented. The piezoelectric patches are fixed on the surface of the host beam based on the Harmonic and Modal analysis done in a Finite Element tool (ANSYS). The dynamic model of the smart beam for the first two modes is obtained using a System Identification technique. The feedback control algorithm is analyzed and is implemented in real-time using National Instruments cRIO 9022 controller. It is observed that with this feedback law 49.29% and 52.84% reduction are obtained for first and second modes of vibration respectively. The result verifies the effectiveness of the controller to suppress the vibration of the smart beam.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.