Abstract
The present study aimed the viability evaluation of solid intramedullary rods made with polyamide 12 and coated with hydroxyapatite in experimentally osteotomized humerus of young roosters (white Plymouth rock). Sixteen animals of 45 days old each were used. After general anesthesia, they underwent to complete transverse osteotomy of the right humerus diaphysis to implant the already described rods which filled the entire length of the medullary cavity and were fixed by two cortical stainless steel screws in each bone fragment. The surgical technique was well succeeded without any trans-operative intercurrence. Through clinical and radiographic examination, it was observed that soon after the anesthesia recovery, six rods (37,5%) broke next to the fracture focus and the same was noticed with the others (62,5%) on seventh day post-surgery. Based on the obtained results, it can be hypothesized that polyamide 12 rods resistance could have been affected by all the thermal stages necessary to its incorporation with hydroxyapatite. Furthermore, the roosters’ age may also have contributed to adverse outcomes. However, future researches will be necessary to confirm those hypotheses.
Highlights
In mammals, osteoshynthesis with intramedullary locked rod (IR) with metallic materials is used due to its facility of execution when compared to other techniques, locking mistakes and movement permanence on fracture’s focus are common (Spadeto Junior et al, 2011)
The present study aimed the viability evaluation of solid intramedullary rods made with polyamide 12 and coated with hydroxyapatite in experimentally osteotomized humerus of young roosters
Cherobini et al (2017) and Dias et al (2018) analyzed the efficiency of massive rods made with polyamide 12 (PA-12) in experimentally induced humeral fractures in adult roosters during 60 days postoperative and they reported that the material have biocompatibility and enough resistance to maintain the fracture focus aligned, allowing osseous consolidation
Summary
Osteoshynthesis with intramedullary locked rod (IR) with metallic materials is used due to its facility of execution when compared to other techniques, locking mistakes and movement permanence on fracture’s focus are common (Spadeto Junior et al, 2011). Abstract The present study aimed the viability evaluation of solid intramedullary rods made with polyamide 12 and coated with hydroxyapatite in experimentally osteotomized humerus of young roosters (white Plymouth rock).
Published Version (
Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have