Abstract
Electropolishing (EP) is a standard process for the treatment of the interior surface of niobium (Nb) superconducting radio-frequency (SRF) cavities used in particle accelerators. We previously conducted a study on vertical electropolishing (VEP), in which the cavity was set vertically during EP of a 1.3 GHz Nb single-cell cavity. In that study, we showed that the major cause of asymmetric removal in VEP is the accumulation of hydrogen gas bubbles, generated during the EP process, on the upper half cell of the cavity. Three types of unique rotating cathodes were tested with the aim to resolve the issues of asymmetric removal and rough surface. Appropriate cathode design and parameters reduced the asymmetric removal in the cell and yielded a smooth surface of the cavity. In this study, we have performed an extensive investigation on VEP of both single- and nine-cell Nb 1.3 GHz cavities with a modified cathode. The VEP parameters with single- and nine-cell coupon cavities were investigated, which facilitate an in situ study of the coupon currents at various positions of the cavities and observation from the viewports located near the iris and equator positions of the cavities. The modified cathode and optimized VEP process for the single-cell cavity yielded uniform removal in the cavity cell and a smooth surface of the interior of the cavity. A novel acid flow method that allows the separation of the acid flow in the cavity and cathode housing was employed in the nine-cell cavity to efficiently remove the gas bubbles from the cavity. The optimized acid flow rates in the cavity and cathode housing, along with other adequate parameters including temperature, cathode rotation speed, and applied voltage, made the surface smooth and significantly reduced the removal nonuniformity in the nine-cell cavity. The single- and nine-cell cavities after an average removal of 46 and $130\text{ }\text{ }\ensuremath{\mu}\mathrm{m}$, respectively, were tested in a vertical cryostat. The single- and nine-cell cavities achieved $31\text{ }\text{ }\mathrm{MV}/\mathrm{m}$ at a ${Q}_{0}$ value of $9\ifmmode\times\else\texttimes\fi{}{10}^{9}$ and $28.3\text{ }\text{ }\mathrm{MV}/\mathrm{m}$ at a ${Q}_{0}$ value of $6.7\ifmmode\times\else\texttimes\fi{}{10}^{9}$, respectively, in the rf tests at the temperature of 2 K. The achieved SRF performances were as good as the baseline performances achieved after the horizontal electropolishing process of the same cavities.
Highlights
The cathode designed with the meshed housing along with optimized parameters including voltage, temperature, acid flow rate, and cathode rotation speed resulted in the desired smooth surface and uniform removal in the single-cell cavities
The results revealed the existence of strong screening of the cathode surface by the exceptionally large quantity of bubbles in the upper part of the cathode housing and upper cells of the cavity
The asymmetric removal and surface roughness were significantly lowered with the dual-flow method, along with the optimized temperature and voltage required for a diffusion-limited removal
Summary
Niobium (Nb) superconducting radio-frequency (SRF) cavities are used in particle accelerators [1] such as the Spallation Neutron Source at Oak Ridge National Laboratory, Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab, European X-ray Free Electron Laser (XFEL), and other proposed accelerators. A good SRF performance of the cavity is attained with a damage- and contaminant-free smooth surface in the interior of the cavity. The top 100–200Àμm-thick surface layer, which is damaged when the cavity is formed, is removed by surface chemistry including buffered chemical polishing (BCP) or electropolishing (EP) [2]. BCP is performed in an acid solution of phosphoric acid (H3PO4), nitric acid (HNO3), and hydrofluoric acid (HF) in a volumetric ratio of 1∶1∶1 or 2∶1∶1 [3]. [4], is performed in an acid solution of sulfuric acid (H2SO4) and HF in a volumetric ratio of 9∶1 and with a counter cathode electrode made of pure aluminum [5]. In BCP, the Nb material is removed
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.