Abstract
A coordinate measurement machine with laser probe was used to measure the vertical distortion of the casts produced by use of three types of impression materials (irreversible hydrocolloid, condensation silicone, and addition silicone) and two types of trays (stock and custom trays). Results indicated that all impression groups showed positive vertical distortion (ranging from 0.00566 to 0.30299 mm) at the edentulous ridges and palatal area. The amount of the vertical distortion was greatest at the palatal area and was followed by the high edentulous ridge and the low edentulous ridge. Addition silicone, with either custom tray or stock tray, was the most accurate impression material. Condensation silicone was more accurate than irreversible hydrocolloid in custom tray impression. However, in stock tray impression the irreversible hydrocolloid was more accurate than the condensation silicone. The results suggest that, with careful manipulation, irreversible hydrocolloid with stock tray impression may provide a satisfactory cast for fabricating the framework of a distal extension removable partial denture.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.