Abstract

A disk type guarded measurement cell is described, which permits the determination of the complex permittivity of liquids with an accuracy of 0.5% or better. The cell has small residual circuit elements (4 nH and 20 mΩ) and behaves like an ideal capacitor for radius-to-electrode spacing ratios ranging from 15 to 135. Ruggedness and ease of use are achieved through a split cell design with a minimal number of parts and threads for assembly, as well as the attachment of fluid lines and electrical connections.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.