Abstract
The function of the breathing apparatus is to protect the health of firefighters in a harmful and non-respirable environment. Closed-circuit breathing apparatus provides members of the Fire and Rescue Service with respiratory protection in the elimination of adverse events in tunnels and underground spaces. The MSA 4h Air Elite is a four-hour self-contained breathing apparatus that operates on the principle of generating oxygen by an exothermic reaction of potassium hyperoxide. Each breathing apparatus has its tactical technical parameters. We verified the tactical and technical data of the MSA AIRE ELITE by the experiment they participated in the firefighter. Each firefighter was equally coupled. An MSA Air Elite was used during the experiment. Tactical-technical data reported by the manufacturer varies in some points with the practical results that we have managed to obtain. The manufacturer's largest deviations in tactical and technical data and practical results are mainly in the length of work activity, temperature in use in intervention, and air consumption. According to our experiment, the MSA 4h Air Elite breathing apparatus does not last in the working activity 240 minutes as it discloses a manufacturer, but on the other hand, this time-inconsistency may be caused by the intensity of training and demanding of the training track.