Abstract
It is demonstrated that if the compact model of a snapback-type device is calibrated using only pulsed I-V data, it may not correctly reproduce the device response to arbitrary electrostatic discharge (ESD) waveforms. Transient I-V measurements are demonstrated to improve the completeness of the device characterization and model verification. Given an accurately calibrated ESD compact model, circuit simulations may be used to identify device-tester interactions that have been reported to cause unexpected damage during ESD testing. The interaction between a snapback device and an ESD tester can be understood in the context of a relaxation oscillator.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEEE Transactions on Device and Materials Reliability
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.