Abstract

Background and Aim: Platelet transfusion plays an important role in the treatment of hematological, oncological, surgical, and transplant patients. Aphaeresis technology is widely available in the world and some part of India, but it is new for our region. The present study aims at various aspects of plateletpheresis including donor safety, donor hematological changes following single donor platelet (SDP) donation, quality of product, and impact on patient following SDP transfusion. Materials and Methods: Preprocedural hematological count such as total platelet count (TPC), hemoglobin, red blood cells, and white blood cells count was recorded. All donors were observed for adverse donor reactions. Postdonation (after 30 min) sample was drawn to see the hematological parameters and compared to that of pre donation hematological parameters. Quality control of all SDP products was done. All recipients were observed for any transfusion reactions. Post 24 h transfusion sample was obtained from the SDP recipient and compared to that of pretransfusion sample to see the platelet increment. Results: A total of 135 plateletpheresis procedures were performed on cell separator. SDP was collected from the donors as per standard operating procedure. All donors were observed for adverse donor reaction. We found an adverse event with one donor. There was decrease in mean value of all hematological parameters in the postdonation sample. There was no thrombocytopenia either clinically or from laboratory value. Similar trend was seen with double yield collection. Mean acid citrate dextrose (ACD) used was 328, mean blood volume processed 3385 ml, mean product volume was 249 ml, mean time was 76.8 min during the procedure. Quality control of all SDP products was done. Mean yield was found to be 4.18 ± 0.95 × 1011 per unit. A positive correlation was seen between pre TPC of donor and product yield. Post 24 h transfusion sample was obtained from the SDP recipient and compared to that of pretransfusion sample to see the platelet increment. We observed mean increment of platelet count to be 76.15 × 109/L. Overall therapeutic benefit was observed in all cases. Conclusion: The study found that plateletpheresis procedure is very safe from donor point of view and SDP product is effective from recipient's point of view.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.