Abstract
Most of the research on the cavitation with entrained air has focused on the military direction, but it ,about centrifugal pumps, which is relevant to people's livelihood, is still relatively lacking. In order to study the basic law of the development of cavitation inside centrifugal pumps under aeration conditions, a test bench suitable for cavitation experiments with incoming flow containing gas was obtained. Furthermore, a single-stage single-suction 6-blade centrifugal pump was used as the research object to conduct pressure pulsation experiments under cavitation condition when the incoming flow was 1.0% air viod fraction at 2900r/min-50m3/h. The results showed that: After cavitation happened, the greater aeration content will deteriorate the pump's anti-cavitation performance, but the head curve is more gentle in falling down compared to natural cavitation. Hence aeration has a beneficial effect on the performance degradation of the pump under the cavitation condition. At the same time, before the cavitation number drops to the fracture cavitation number of the pump, aeration has improvement in the efficiency of the pump in different degrees , especially in the situation with the ventilated rate of 1.0%. The main frequency of pressure pulsation at the inlet and outlet of the test pump after aeration is dominated by the blade frequency. The shaft frequency signal at the outlet gradually decreases with the cavitation number lessened. Moreover the amplitude of the blade frequency grows slightly with the reduction of the cavitation number. But it tends to soar when the cavitation number is less than the fracture cavitation number.
Highlights
Cavitation happens when the local pressure inside the centrifugal pump falls to the vaporization pressure of the fluid
Figure 4 illustrates the cavitation performance curve of the test pump at 2900 r/min at three kind of rates with entrained air compared with the natural cavitation curve
When the content of entrained air is 0.3%, the head starts to drop steeply from δ=0.08397, which is much earlier than the natural cavitation head steep drop point, but the trend of head drop is smoother than the natural cavitation condition
Summary
Most of the research on the cavitation with entrained air has focused on the military direction, but it ,about centrifugal pumps, which is relevant to people's livelihood, is still relatively lacking. In order to study the basic law of the development of cavitation inside centrifugal pumps under aeration conditions, a test bench suitable for cavitation experiments with incoming flow containing gas was obtained. A single-stage single-suction 6-blade centrifugal pump was used as the research object to conduct pressure pulsation experiments under cavitation condition when the incoming flow was 1.0% air viod fraction at 2900r/min-50m3/h. The main frequency of pressure pulsation at the inlet and outlet of the test pump after aeration is dominated by the blade frequency. The amplitude of the blade frequency grows slightly with the reduction of the cavitation number. It tends to soar when the cavitation number is less than the fracture cavitation number
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.