Abstract

Concerning the development of cavitation in a centrifugal pump, numerical simulations and experimental investigations have been carried out in a closed hydraulic test rig. The internal flow characteristics and pressure pulsation at pump inlet and outlet have been analyzed during the process of cavitation development. The results of the research reveal the occurrence and development of cavitation in the centrifugal pump which has been confirmed through experiments and numerical simulation. The degree of pump cavitation could be monitored through pump inlet and outlet pressure pulsation. Compared with pump outlet pressure pulsation, pump inlet pressure pulsation is more sensitive to the change of cavitation. According to the results of the investigation, the typical frequency of pump inlet pressure pulsation could be regarded as around 30 Hz in the severe cavitation conditions. Meanwhile, the pump head dropped by 0.77% from noncavitation conditions which could be regarded as a symbol of incipient cavitation.