Abstract
Impact insulation class testing per ASTM E 492 requires measurement of the sound field at exactly four tapping machine positions. Previous research by the authors [J. Acoust. Soc. Am. 121, 3113 (2007), J. Acoust. Soc. Am. 122, 2955 (2007)] indicated that for field tests, the variation between tapping machine positions was small. To our knowledge, a systematic investigation has not been performed for tapping machine positions in the laboratory, and some recent results indicate that the variation may be larger than expected. Large variation in sound level may be inherent to the method, or may point to problems in construction or installation of flooring materials. The variations with tapping machine position are analyzed for a set of laboratory tests, and the previous field test studies are updated with additional data. The authors investigate possible changes to the standards to mandate a maximum allowable variation between tapping machine positions, and to require additional positions as necessary.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have