Abstract

Statement of problemDifferent parameters affect the marginal and internal fit of zirconia fixed partial dentures (FPDs) on natural teeth. Determining a way to optimize these restorations is essential. PurposeThe purpose of this systematic review was to determine the variables affecting the marginal fit and internal accuracy of zirconia FPDs on natural teeth. Material and methodsAn electronic search was conducted by 2 independent reviewers by using the MEDLINE, Cochrane, Web of Science, and Scopus databases, as well as Google Scholar, for studies published up to July 2018, and a manual search was conducted from the reference lists of related articles. Eligibility criteria included articles in English published in peer-reviewed journals that assessed the marginal and/or internal adaptation of zirconia FPDs on teeth with 3 or more units, with at least 1 of the experimental groups being frameworks or FPDs fabricated from zirconia. Risk of bias was assessed with the aid of the Cochrane Handbook for Systematic Reviews of Interventions. ResultsThe search provided 418 records, with 41 fulfilling the inclusion criteria. The selected studies showed considerable heterogeneity regarding materials, state of sintering, manufacturer and computer-aided design and computer-aided manufacturing (CAD-CAM) system, experimental methodology, sample size, and span length. Of the included articles, 36 were in vitro studies and 5 were clinical studies, most of which exhibited high-performance and detection biases. CAD-CAM systems provided more precise marginal and internal fit than CAM systems. An increase of framework span length to 6 or more units decreased both marginal and internal fit. The reported marginal gap tended to increase after the veneering process. The introduction of a conventional impression into an otherwise digital workflow seems to have a negative effect on the marginal fit. ConclusionsThe accuracy of zirconia FPDs or frameworks is considerably influenced by the processing procedure used and the choice of CAD-CAM system.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call