Abstract

For high input voltage (>;264 Vac) ac/dc applications, a buck power factor correction (PFC) converter is a good choice because of its low output voltage, high efficiency, lifetime improvement, and cost reduction by using a low voltage rating (<;200 V) electrolytic capacitor. However, due to the inherent dead angle of the input current, the harmonics of the buck PFC converter are high, which limits its application in lighting systems. In order to make the buck PFC converter meet the harmonics requirements (IEC61000-3-2, Class C) in lighting applications, this paper proposes a variable on-time controller for a critical conduction mode (CRM) buck PFC front-end converter for isolated high-brightness LED applications. By feedforwarding the input voltage and regulating the on-time of the switch, the high-order harmonics can be reduced to meet the lighting system limitations. Experimental results obtained on a 150-W CRM buck front-end PFC prototype show that the efficiency of buck PFC exceeds 96% during the entire line input range (250-530 Vac) at full load, and the current harmonics content can meet the harmonic requirements.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.