Abstract
The vapor pressure of silver bromide (AgBr) liquid was measured by the Knudsen effusion method. The ratio of the vapor species of silver bromide was calculated from the literature Hildenbrand and Lau, Pankratz [3,6], and the vapor pressures were calculated on the basis of the ratio. As reported in the literature Hildenbrand and Lau [3], we considered the vapor species to be monomers (AgBr) and trimers (Ag3Br3). The partial pressures of AgBr [pmonomer(Pa)] and Ag3Br3 [ptrimer(Pa)] were respectively fitted by the following linear equations over the temperature range 829.9–929.9 K:lnpmonomer= -(23590 ± 519) / T + 25.22 ± 0.59,ln(ptrimer) = -(19449 ± 509) / T + (20.42 ± 0.58).The total vapor pressure of silver bromide [ptotal(Pa)] fitted the following linear equation:ln(ptotal) = -(21653 ± 529) / T + (23.72 ± 0.60).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.