Abstract

This study was performed to check the validity of and propose a cutoff point for measuring the neck circumference for screening hypoxia occurrence in patients undergoing sedative endoscopy. Data were collected from 168 patients who visited the Endoscopy Center of G University Hospital between 27 April 2020 and 12 June 2020 to undergo sedative endoscopy. Hypoxia occurrences were measured using sleep questionnaires (STOP-BANG and Berlin questionnaires), and the neck circumference measurements of the patients were compared. Neck circumference as a predictor of hypoxia and its sensitivity and specificity according to the cutoff values were high; thus, it is a valid screening test for hypoxia in patients undergoing sedative endoscopy. The most appropriate cutoff values for sitting neck circumference and lying neck circumference in men were 40.5 and 40.3, respectively, and those for women were 35.3 and 35.8, respectively. Hypoxia can be predicted in patients undergoing sedative endoscopy by measuring their neck circumference.