Abstract

Tamarindus indica L is a medicinal plant that has many benefits. One of the chemical compounds contained therein is the flavonoid quercetin type. The number of herbal products on the market makes the quality assurance of herbal products need to be done by performing the assay of the active compounds using validated methods. This study aims to validate the assay method quercetin in the extract of tamarind leaves. Tamarind leaf extract was macerated with hexane; then, it was re-macerated with 70% ethanol. The extract was concentrated using a rotary evaporator. The assay was performed using the UV-Vis Spectrophotometry method, and parameter validation specified in this study, including linearity, LOD, LOQ, precision, and accuracy. Quercetin level obtained in extracts of tamarind leaves was at 21.52 mg/g. Based on the test method validation, the correlation coefficient (r) was 0.9999, the regression function coefficients (Vx0) was 0.59545%, LOD 0.1515 ppm, LOQ 0.4592 ppm, coefficient of variation precision was less than 2%, and recoveries range was in 97-103%. Tamarindus indica L is a medicinal plant that has many benefits. One of the chemical compounds contained therein is the flavonoid quercetin type. The number of herbal products on the market makes the quality assurance of herbal products need to be done by performing the assay of the active compounds using validated methods. This study aims to validate the assay method quercetin in the extract of tamarind leaves. Tamarind leaf extract was macerated with hexane; then, it was re-macerated with 70% ethanol. The extract was concentrated using a rotary evaporator. The assay was performed using the UV-Vis Spectrophotometry method, and parameter validation specified in this study, including linearity, LOD, LOQ, precision, and accuracy. Quercetin level obtained in extracts of tamarind leaves was at 21.52 mg/g. Based on the test method validation, the correlation coefficient (r) was 0.9999, the regression function coefficients (Vx0) was 0.59545%, LOD 0.1515 ppm, LOQ 0.4592 ppm, coefficient of variation precision was less than 2%, and recoveries range was in 97-103%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.