Abstract

The Advanced Bionics® (AB)-York crescent of sound is a new test setup that comprises speech intelligibility in noise and localization tests that represent everyday listening situations. One of its tests is the Sentence Test with Adaptive Randomized Roving levels (STARR) with sentences and noise both presented from straight ahead. For the Dutch population, we adopted the AB-York setup and replaced the English sentences with a validated set of Dutch sentences. The Dutch version of the STARR is called the Utrecht-STARR (U-STARR). This study primarily assesses the validity and reliability of the U-STARR compared to the Plomp test, which is the current Dutch gold standard for speech-in-noise testing. The outcome of both tests is a speech reception threshold in noise (SRTn). Secondary outcomes are the SRTn measured with sounds from spatially separated sources (SISSS) as well as sound localization capability. We tested 29 normal-hearing adults and 18 postlingually deafened adult patients with unilateral cochlear implants (CI). This study shows that the U-STARR is adequate and reliable and seems better suited for severely hearing-impaired persons than the conventional Plomp test. Further, CI patients have poor spatial listening skills, as demonstrated with the AB-York test.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.