Abstract
We complete the first validation campaign of the Cryogenic Circuit Conductor and Coil (4C) code, focusing on the cryogenic circuit module of 4C, which is based on the component models from the recently developed “Cryogenics” Modelica library. Measured data from the HELIOS facility (HElium Loop for hIgh LOads Smoothing) at CEA Grenoble, France, are used as reference. HELIOS includes a supercritical He loop (cold circulator, pipes equipped with resistive heaters, control and bypass valves, heat exchangers) and a saturated He bath. A repetitive heat pulse test is simulated with 4C. The computed evolution of temperature, pressure and mass flow rate at different circuit locations, both in the loop and in the bath, shows a very good agreement with the measurements.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.