Abstract

A liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and fully validated, according to U.S. Food and Drug Administration guidance, for the simultaneous determination of phenylmercapturic acid, benzylmercapturic acid and o-methylbenzyl mercapturic acid in human urine as biomarkers of exposure to benzene, toluene and xylenes (BTX). After solid phase extraction and LC separation, samples were analyzed by a triple–quadrupole mass spectrometer operated in negative ion mode, using isotope-labeled analogs as internal standards (ISs). The method meets all the validation criteria required. The limits of detection of the three analytes, ranging from 0.30 to 0.40 μg l −1, and the high throughput make the method suitable for the routine biological monitoring of co-exposure to BTX both in the occupational and environmental settings. The validated method was applied to assess exposure to BTX in a group of 354 urban traffic wardens.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.