Abstract

A stability-indicating reversed-phase high performance liquid chromatographic (HPLC) method has been developed and validated for the assay of formoterol fumarate and the related substances, namely, formoterol fumarate desformyl and formoterol fumarate acetamide analogs, in the active pharmaceutical ingredient. The separation was achieved by isocratic elution using an Alltech Alltima C 18 (150×4.6 mm) column, a mobile phase consisting of ammonium acetate (50 mM; pH 5.0)–ethanol (65:35, v/v), a flow rate of 1.0 ml/min and UV detection at 242 nm. The detection and quantitation limits were 0.03 and 08 μg/ml, respectively, while the linear range of detection was between 0.03 and 255 μg/ml. Comparative determinations of formoterol fumarate in three lots of bulk drugs using the proposed HPLC method and the standard potentiometric titration method of pharmacopoeia show that both methods are equivalent for pure drug substance assay. However, the HPLC method allowed the separation and quantitation of the impurities not achievable with the official methods in the bulk drugs. This study shows that the proposed method is accurate, linear, and sensitive as stability indicating assay method for formoterol fumarate in the bulk drug.