Abstract

The objectives of this study were to (1) validate a method using refractometry to rapidly and accurately determine immunoglobulin (IgG) concentration in Jersey colostrum, (2) determine whether there should be different refractive index (nD) and %Brix cut points for Jersey colostrum, and (3) evaluate the effect of multiple freeze–thaw (FT) cycles on radial immunodiffusion (RID) and a digital refractometer to determine IgG concentration in Jersey colostrum. Samples (n=58; 3L) of colostrum were collected from a dairy in northwestern Iowa. Samples were analyzed within 2h of collection for IgG concentration by RID, %Brix, and nD by refractometer and an estimate of IgG by colostrometer. Samples were frozen, placed on dry ice, and transported to the laboratory at Iowa State University (Ames). Samples arrived frozen and were placed in a −20°C manual-defrost freezer until further analysis. On d 7 (1FT), d 14 (2FT), and 1yr (3FT) all samples were thawed, analyzed for IgG by RID, %Brix, nD by refractometer, and IgG estimate by colostrometer, and frozen until reanalysis at the next time point. Fresh colostrum had a mean (±SD) IgG concentration of 72.91 (±33.53) mg/mL, 21.24% (±4.43) Brix, and nD 1.3669 (±0.0074). Multiple FT cycles did affect IgG as determined by RID and colostrometer reading. The IgG concentrations were greater in fresh and 1FT samples as compared with 2FT and 3FT samples (72.91, 75.38, 67.20, and 67.31mg of IgG/mL, respectively). The colostrometer reading was lower in 1FT samples compared with fresh and 2FT samples. Multiple FT cycles had no effect on nD or %Brix reading. In fresh samples, IgG concentration was moderately correlated with nD (r=0.79), %Brix (r=0.79), and colostrometer reading (r=0.79). Diagnostic test characteristics using the recommended cut point of 1.35966 nD resulted in similar sensitivities for 1FT and 2 FT samples (94.87 and 94.74%, respectively). Cut points of 18 and 19% Brix resulted in the greatest sensitivities (92.31 and 84.62%) and specificity (94.74 and 94.74%, respectively). The 18% Brix cut point resulted in 94.83% of the samples being correctly classified based on IgG concentration. These data support the use of digital refractometer to accurately and rapidly determine IgG concentration in fresh Jersey colostrum. Additionally, these data suggest that IgG concentration determined by RID is affected by multiple FT cycles, whereas estimates obtained by refractometer are not affected by multiple FT cycles.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call