Abstract

Two chromatographic methods were developed, optimized and validated for simultaneous determination of calcipotriol monohydrate (CPM) and betamethasone dipropionate (BMD) in the presence of two dosage form additives named; butylated hydroxytoluene (BHT) and alpha-tocopherol (TOCO). The proposed methods were accurate, sensitive and specific. The first method based on using aluminum thin-layer chromatographic plates precoated with silica gel GF254 as a stationary phase and chloroform-ethyl acetate-toluene (5:5:3, by volume) as a developing system. This was followed by densitometric measurement of the separated bands at 264 nm. Whereas the second method is RP-HPLC where OnyxMonolithic C18® column was used with a gradient profile using methanol, water and acetic acid at flow rate 2.0 mL min-1. Detection was carried out at 264 nm. The methods were validated according to ICH guidelines. The specificity of the developed methods was investigated by analyzing the pharmaceutical dosage form. The validity of the proposed methods was assessed using the standard addition technique. The obtained results were statistically compared with those obtained by the official methods, showing no significant difference with respect to accuracy and precision at P = 0.05.