It is shown that for every input range and meter a set of optimum conditions exist, which insure maximum readability, economy, and minimum operating current. Equations are developed (and illustrated with several examples) for the rapid design of a meter for a predetermined range. Optimum conditions are imposed. The dependence of the range secured upon plate circuit impedance is shown and its variation with frequency explained. The procedure for eliminating frequency error up to and including radio frequencies is illustrated.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.