Abstract
The exothermic decomposition of cumene hydroperoxide (CHP) in cumene liquid was characterized by isothermal microcalorimetry, involving the thermal activity monitor (TAM). Unlike the exothermic behaviors previously determined from an adiabatic calorimeter, such as the vent sizing package 2 (VSP2), or differential scanning calorimetry (DSC), thermal curves revealed that CHP undergoes an autocatalytic decomposition detectable between 75 and 90°C. Previous studies have shown that the CHP in a temperature range higher than 100°C conformed to an nth order reaction rate model. CHP heat of decomposition and autocatalytic kinetics behavior were measured and compared with previous reports, and the methodology and the advantages of using the TAM to obtain an autocatalytic model by curve fitting are reported. With various autocatalytic models, such as the Prout-Tompkins equation and the Avrami-Erofeev rate law, the best curve fit among models was also investigated and proposed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.