Abstract
Technique of measurement energy density of high-current electron beam by means of dosimetric field of POR type (5-50 kGy) and standard scanner is presented. Also is shown that relative optical density of the film increases linear to increasing of absorbed dose in the range of absorbed dose 5-120 kGy. Correlation dependence of digital image parameter light of irradiated samples of dosimetric film on samples relative optical density is obtained. By means of correlation function, two-dimensional matrix of absorbed dose's values, corresponding with electron beam autograph on dosimetric film is derived. Elaborated technique allows to measure nonuniformity of energy density of pulsed electron beam with spatial definition less than 1 mm during the measurement of absolute values of energy density.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.