Abstract

We present results and discussion on the positive impact of ionizer(s) used in multiple configurations on wafer backside and front-side particle adders in physical vapor deposition (PVD) processing tools. We provide a hypothesis, followed by testing, that establishes a relationship between electrical surface charge collection data and particle data obtained in a laboratory setting as well as a real-world wafer fabrication facility environment. For chip manufacturers, controlling surface charges on production wafers results in a reduced number of undesirable particles, thereby resulting in higher yield, more reliable final product chips, and reduced product losses. And for equipment manufacturers, more reliable and better tool performance can lead to increased productivity. The INOVA PVD system's good particle performance, as demonstrated on good quality wafers, is made marginal quality wafersmore robust with an ionizer installation when marginal quality wafers are used.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.