Abstract

Continuous monitoring of arterial blood pressure (ABP) of patients in hospital is currently carried out in an invasive way, which could represent a risk for them. In this paper, a noninvasive methodology to optimize ABP estimators using electrocardiogram and photoplethysmography signals is proposed. For this, the XGBoost machine learning model, optimized with Bayesian techniques, is executed in a Graphics Processing Unit, which drastically reduces execution time. The methodology is evaluated using the MIMIC-III Waveform Database. Systolic and diastolic pressures are estimated with mean absolute error values of 15.85 and 11.59 mmHg, respectively, similar to those of the state of the art. The main advantage of the proposed methodology with respect to others of the current state of the art is that it allows the optimization of the estimator model to be performed automatically and more efficiently at the computational level for the data available. Clinical Relevance- This approach has the advantage of using noninvasive methods to continuously monitor patient's arterial blood pressure, reducing the risk for patients.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.