Abstract
The study was conducted from September 2020 to December 2022 at the Infermi Hospital in Rimini. Central venous catheters were placed using the SIC bundle for insertion. Dialkylcarbamoylchloride dressing was placed below the subcutaneous anchoring at the time of CVC placement and at each dressing change. Data about the catheters and the exit site were recorded and then compared with an historical cohort. 118 catheters were placed during the studied period. The dialkylcarbamoylchloride dressing was well-tolerated. No case of systemic or local infection was recorded. The comparison with the historical cohort showed a reduction in the rate of exit site infection (p value 0.03). Dialkylcarbamoylchloride dressing is well-tolerated in paediatric and neonatal population. It represents a promising tool as a strategy for infection prevention.