Abstract

To determine phenol red thread test (PRTT) values in eyes of clinically normal Hispaniolan Amazon parrots before and after topical application of an ophthalmic anesthetic agent and compare findings with Schirmer tear test (STT) values. Evaluation study. 24 Amazona ventralis parrots from a research colony. On 4 occasions (1-week intervals), all birds underwent a thorough ophthalmic examination of both eyes, which included (in sequence) performance of a PRTT and an STT; topical ocular application of proparacaine hydrochloride; and performance of another PRTT and another STT. Correlations between PRTT and STT values recorded with and without topical anesthesia were assessed. Without topical anesthesia, mean +/- SD PRTT value was 12.5 +/- 5.0 mm/15 s (range, 1 to 25 mm/15 s). With topical anesthesia, the PRTT value was 12.6 +/- 5.4 mm/15 s (range, 2 to 24 mm/15 s). Without topical anesthesia, mean STT value was 7.9 +/- 2.6 mm/min (range, 0 to 13 mm/min). With topical anesthesia, the STT value was 5.1 +/- 3.3 mm/min (range, 0 to 18 mm/min). The correlation of PRTT and STT values recorded with or without topical anesthesia was weak (r = 0.51 and r = 0.32, respectively). Results indicated that the PRTT and STT were both viable methods for measurement of tear production in Hispaniolan Amazon parrots. Topical application of an ophthalmic anesthetic agent did not have a significant effect on the PRTT values but significantly decreased the STT values.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call