Abstract

To increase the efficiency of a combined-cycle gas turbine (CCGT) power plant, an innovative system was built to recycle its internal unutilized energy and increase the heatingoutput. CCGT circulation and absorption heat pump circulation were combined in the new system, and latent heat recovery from LNG combustion was realized with very slight power consumption. The innovative system was applied in a 200-MW power plant, and real operation data were obtained to design optimal temperature and flow rate balance. Finally, the effect of system transformation on the efficiency increase was analyzed. The proposed system enhanced the overall primary energy efficiency of cogeneration and thermal output by 2.6 and 7.4%, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.