Abstract

Two functions namely initial lung deposition and lung retention per unit faecal excretion rate are constructed primarily based on the excretion pattern of four subjects exposed to (239)Pu. In the absence of initial clear knowledge about the class of compound inhaled, faecal to urine excretion ratio was used to infer the type of inhaled class. Trends in the urine and faecal data had suggested that the intake was due to mixed class of plutonium compound for each case. With the assumption of 1:1 mixture of plutonium M&S class inhaled compound, faecal excretion rates for only S-class intake were worked out. Uptake inferred based on their urinary data had suggested it to be of similar level within 40% of uncertainty for 5 microm particle size distribution. Data, all the four cases, were pooled for analysis citing the similar level of intake, particle size distribution, nature and pattern of work. The function obtained was tested for S-class lung retention and faecal excretion rate value. These functions are handy tool for estimating initial lung burden and lung retention value for low level of S-class plutonium intake based on subject faecal analysis data.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.