Abstract

Although previous research show high correlation between fat-free mass (FFM) measured by bioelectrical impedance analysis (BIA) and dual-energy X-ray absorptiometry (DXA), the validity of BIA to track longitudinal changes in FFM is uncertain. Thus, the aim of this study was to validate the ability of BIA to assess changes in FFM during 6 months of recovery from non-metastatic colorectal cancer (CRC). A total of 136 women and men (50-80 years) with stage I-III CRC and a wide range of baseline FFM (35.7-73.5kg) were included in the study. Body composition was measured at study baseline within 2-9 months of surgery and again 6 months later. Whole-body BIA FFM estimates (FFMBIA) were calculated using three different equations (manufacturer's, Schols' and Gray's) before comparison to FFM estimates obtained by DXA (FFMDXA). Correlation between changes in FFMBIA and FFMDXA was intermediate regardless of equation (r≈0.6). The difference in change of FFMBIA was significant compared to FFMDXA, using all three equations and BIA overestimated both loss and gain. However, BIA showed 100% sensitivity and about 90% specificity to identify individuals with ≥5% loss in FFM, using all three equations. Sensitivity of FFMBIA to detect a smaller loss of FFM (60-76%) or a gain in FFM of ≥5% (33-62%) was poor. In a well-nourished population of non-metastatic CRC patients, a single-frequency whole-body BIA device yielded imprecise data on changes in FFM, regardless of equation. BIA is thus not a valid option for quantifying changes in FFM in individuals. However, BIA could be used to identify patients with loss in FFM ≥5% in this population. The validity of BIA to monitor changes in FFM warrants further investigation before implementation in clinical praxis.

Highlights

  • Colorectal cancer (CRC) is among the most common cancers worldwide and a leading cause of cancer deaths [1]

  • The aim of the current study was to validate the ability of a whole-body bioelectrical impedance analysis (BIA), compared to dual-energy X-ray absorptiometry (DXA), to track and identify changes in fat-free mass (FFM) during 6 months in a heterogeneous group of non-metastatic CRC patients in recovery from surgery

  • Out of the 158 patients included at data extraction, N 1⁄4 16 had missing DXA or BIA data at one or both time points

Read more

Summary

Introduction

Colorectal cancer (CRC) is among the most common cancers worldwide and a leading cause of cancer deaths [1]. The aim of this study was to validate the ability of BIA to assess changes in FFM during 6 months of recovery from non-metastatic colorectal cancer (CRC). Whole-body BIA FFM estimates (FFMBIA) were calculated using three different equations (manufacturer's, Schols' and Gray's) before comparison to FFM estimates obtained by DXA (FFMDXA). Results: Correlation between changes in FFMBIA and FFMDXA was intermediate regardless of equation (r z 0.6). The difference in change of FFMBIA was significant compared to FFMDXA, using all three equations and BIA overestimated both loss and gain. BIA showed 100% sensitivity and about 90% specificity to identify individuals with !5% loss in FFM, using all three equations. Conclusion: In a well-nourished population of non-metastatic CRC patients, a single-frequency wholebody BIA device yielded imprecise data on changes in FFM, regardless of equation.

Objectives
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.