Abstract

To report the use of a rotational thrombectomy device for recanalization of a thrombosed hepatic artery bypass graft in an orthotopic liver transplant (OLT). Six months after a second OLT in a 52-year-old man, an iliac conduit used for an aortohepatic bypass became occluded, interrupting arterial supply to the liver transplant. The 8-F Straub Rotarex system was used to successfully remove clot from the bypass graft, avoiding embolization to the hepatic arteries. The recanalized conduit has remained patent for 1 year with the patient on an anticoagulation regimen. The Rotarex thrombectomy system may be considered an alternative to other percutaneous interventions for the treatment of occluded bypass conduits supplying a liver transplant.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call