A 10-year-old male Korean domestic short-haired cat was presented with refractory lower urinary tract obstruction. The cat was treated by urethral stent placement using a self-expanding nitinol intraluminal stent (Zilver 535 biliary stents, COOK, U.S.A.) subsequent with balloon expansion. Although the cat showed 2 days of transient hematuria after the stent placement, no further obstruction was occurred after the stent placement. Follow-up studies performed at monthly intervals have found no re-stenosis or particular complications, to date.
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.