Abstract
Fission counters have been developed indigenously, using 233U as a sensing material for reactor startup applications. The first model has a counting sensitivity of 0.003 cps/nv in the pulse mode, 1×10−15 A/nv in the dc mode, and 6.4×10−29 A2 Hz/nv in the Campbell mode. A more sensitive counter with about 75 mg of 233U showed an average sensitivity of 0.02 cps/nv. A proposal for 233U in-core miniature dc fission chambers is discussed. A design for high sensitivity (0.5 cps/nv) U-233 pulse counter with transmission line-type readout is also proposed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.