Abstract
The study presented in this paper is based on measurements conducted in the MINERVE zero power reactor operated at CEA Cadarache with a CEA-made U-235 miniature fission chamber (8 mm in diameter) and obtained in both pulse and Campbelling modes. Our objective was to investigate the impact of the filling gas mixture and pressure on each operating mode, using the capacity of the chamber to be refilled with gas. Three gas mixtures were tested (pure Ar, Ar+4%N <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> and Ar+10%CH <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">4</sub> ) with pressure ranging from 1 to 9 bars. The Mean Fission Product Charge (MFPC), which is the mean charge deposited in the gas by fission products, was obtained from pulse mode signals for each detector setting. It is shown the MFPC is another key parameter to optimize the detector neutron sensitivity, after the fissile coating cross section. Campbelling mode signal was acquired with the Fast Neutron Detector System (FNDS) recently developed by CEA and SCK·CEN. Interesting results were obtained which improve our knowledge of the detector operation. Firstly, it was found that the measurements obtained in both modes are very consistent. The MFPC as a function of the gas pressure was found to be not monotonic. Instead, it features a maximum between 3 and 4 bars. This behavior is expected if the detector does not operate in saturation regime. Indeed, our standard voltage bias of 300 V appeared to be not high enough so that the saturation regime is established. Saturation curves measured in Campbelling mode were fitted using a detector modeling in order to extrapolate the saturation regime MFPC, which came to be independent from the gas. Secondly, obtained results show that the measuring range in Campbelling mode with this detector starts from fission rates as low as a few thousand counts per second. So the so called overlapping range, in which both pulse and Campbelling modes are usable, is about one decade with our spectroscopy modules and more than two decades with fast counting electronic modules. This feature is of high interest to test and/or calibrate Campbelling mode electronic systems using the MINERVE ZPR.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.