Abstract

We evaluate the effect of the emmetropization technique LASIK (laser-assisted in situ keratomileusis) on stereoscopic vision. For this, we used a mirror stereoscope to measure the upper disparity limit D(max) before (with best correction) and after LASIK for 30 patients. The results show that the upper disparity limit declines from 41.1 min of arc on average to 31.3 min of arc after LASIK, being significant in 83% of the patients. This deterioration is significantly correlated with an increase in the postsurgical interocular differences in higher-order aberrations, corneal asphericity, and presurgical anisometropia. New ablation algorithms should minimize interocular differences in order to improve binocular visual performance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.