Abstract

To analyze the influence of higher-order aberrations on binocular visual performance under mesopic conditions. We measured aberrations in both eyes of 35 emmetropic observers with a Wasca aberrometer. Binocular visual performance was checked with both binocular summation for contrast sensitivity function and a parameter that characterizes stereopsis (maximum disparity). Binocular summation and maximum disparity significantly decrease with increasing interocular differences in higher-order aberrations (total, coma, and spherical aberration). At least some aspects of binocular visual performance are less effective for large interocular differences in higher-order eye aberrations.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.