Abstract
Uneven dielectric barrier discharge (DBD) reactors driven by positive–negative pulse plasma discharges were investigated for particulate matter (PM) removal from a diesel engine. Two kinds of uneven alumina plates and three kinds of uneven stainless steel plates were used to assemble six kinds of uneven DBD reactors of discharge gaps 0.4–1.0 mm. The experimental results show that PM from diesel engines can be removed using the uneven DBD reactors. The maximum PM removal was 67% at 300 W energy injections using the DBD reactor of 0.4 mm gap distance. PM removal increased with decreasing gap distance. The energy efficiency using the uneven DBD reactor of a shorter gap distance was higher than that using the uneven DBD reactor of a longer gap distance as the uneven DBD reactor of a shorter gap distance has a higher PM deposition rate. The energy efficiency was typically in a range of 3–10.6 g/kWh at an energy density of 2–16 J/L. A comparison of this study with reports given by other research groups is given.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.