Abstract

Surface flashover voltage on solid insulators in gas cooled superconducting power devices is studied. The relationship between the surface flashover voltage and the dielectric strength of the gas media is established. Analysis of the data on surface flashover voltage measurements on cylindrical samples made of high-pressure fiberglass laminate (G10) in three different gas media with varying dielectric strength and pressure showed a positive correlation between the surface flashover voltage and the dielectric strength of the gas both at room temperature and 77 K. The positive relationship, however, is not linear. The results suggest that using gas media with higher dielectric strength, employing higher pressure, and lowering temperature in HTS power devices leads to higher surface flashover voltages and higher operating voltages because surface flashover is usually the limiting voltage in devices that use solid support structures and possess voltage gradients.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.