Abstract

BackgroundCurrently, no normal ultrasound data of the fetuses during the 20–40 gestation have been obtained for references of fetal growth and development. If such ultrasound data existed for prenatal diagnosis of possible diseases and abnormalities, neonates would be able to get timely treatment immediately after birth. This study was thus performed to obtain ultrasound parameters of normal fetuses during the 20–40 week gestation and the distribution of ultrasound parameters with the gestational age for references of detecting potential fetal diseases and abnormalities.MethodsNormal fetuses without any abnormalities were enrolled, and the ultrasound parameters of the general biology, arteries, and aorta were measured and analyzed.Results417 normal fetuses were enrolled. A significant (P < 0.05) negative correlation with the gestational age was detected in the peak systolic velocity/peak diastolic velocity (S/D), pulsatility index (PI) and resistance index (RI) of the umbilical artery (UA). A relatively stable relationship with the gestational age was detected in the fetal weight%, S/D, PI and RI of the middle cerebral artery (MCA), peak systolic velocity (PSV) and velocity time integral (VTI) of the intra-abdominal UA, fetal heart to chest ratio, mitral valve (MV)- and tricuspid valve (TV)-E/A peak flow velocity, aortic isthmic Z-score and displacement, distance between the brachiocephalic artery-left common carotid artery (BA-LCCA) and LCCA-left subclavian artery (LSA), Z-score of aorta, ascending aorta (AAO), pulmonary artery (PA), main pulmonary artery (MPA), and descending aorta (DAO). A significant (P < 0.05) positive correlation with the gestational age was detected in the fetal biological data, MCA PSV and VTI, free-UA PSV and VTI and cardio-thoracic ratio, cardiac parameters, ductus arteriosus (DA) and isthmus diameter, aortic parameters, PA and MPA diameter, MPA PSV and VTI, isthmus flow volume and velocity and PA flow volume, DA and BA parameters, and LCCA and LSA parameters (flow volume, PSV, and VTI).ConclusionA certain correlation and distribution trend is detected in the ultrasound parameters of normal fetuses, and the ratios among different parameters remain relative stable. These findings can be used for determination of abnormal growth of the fetuses in prenatal ultrasound scan.Graphic

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.