Abstract

Much attention is given to the consequences of airborne particles on human health and well-being. Wear is one source of airborne particles and contributions in the urban environments from wheel-to-rail contacts and disc brakes cannot be neglected. Traditionally, mechanical wear has been associated with the generation of particles of diameters of some microns. However, the research described has found ultrafine particle generation from wear processes.Particle generation from wear was measured under controlled laboratory conditions. The wear was created through sliding contact in a tribometer (type “pin-on-disc”) with different materials and with different sliding velocities and pressures, to represent rail traffic and automobile disc braking. Particle concentrations and size distributions in the air were determined for particle diameters from 10 nm up to more than 10 μm. For most materials and conditions three particle size modes were found: one at 50–100 nm, one at a few hundred nm and one at a few μm particle diameter.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.