Abstract

An analysis of the ultimate strength of a cracked stiffened panel repaired by carbon fibre reinforced polymer (CFRP) under axial compression is presented. The analysis method adopts the nonlinear mechanics of adhesives in the interaction of CFRP with the steel structure. The numerical model is validated by tests of cracked plates repaired by CFRP. The collapse of the cracked stiffened panel repaired by CFRP revealed that the debonding of CFRP happens after buckling. The CFRP repair can recover the ultimate strength of the cracked structure to the one of the intact panel. A series of analysis is performed with the validated numerical model to investigate the effects of geometry, configuration of CFRP and crack length on the ultimate strength. Crack treatment with stop holes is also studied, and the results show that the repair of the CFRP can recover the ultimate strength of the cracked stiffened panel with the occurrence of the stop holes, at the same time as it may reduce the stress levels significantly.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.