This paper is concerned with the ultimate behavior of composite floor slabs under extreme loading situations resembling those occurring during severe building fires. The study focuses on the failure state associated with rupture of the reinforcement in idealized slab elements, which become lightly reinforced in a fire situation due to the early loss of the steel deck. The paper describes a fundamental approach for assessing the failure limit associated with reinforcement fracture in lightly reinforced beams, representing idealized slab strips. A description of the ambient-temperature tests on isolated restrained elements, carried out to assess the influence of key material parameters on the failure conditions, is firstly presented. The results of a series of material tests, undertaken mainly to examine the effect of elevated temperature on ductility, are also described. A simplified analytical model is employed, in conjunction with the experimental findings, to assess the salient material parameters and their implications on the ultimate response at both ambient and elevated temperature.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.