Abstract
Hydrogen is a renewable energy source with the potential to replace fossil fuels due to its eco-friendly nature. This study aims to conduct a performance test of dry cell electrolyzer with variations in KOH electrolyte concentration so that optimal hydrogen production in fuel cells can be determined. The dry cell was chosen to mitigate explosion risks in wet cells caused by short circuits and uncontrolled gas pressure in previous studies. KOH concentrations from 0.1 M to 0.5 M were tested at 10 V and 12 V for 30 minutes. The results indicate that a 0.3 M concentration at 12 V achieved the highest hydrogen yield of 1.1829 liters. The optimum condition was found at 0.3 M and 10 V with 37% efficiency, producing 0.8206 liters of hydrogen with an SEC of 31,656.65 J/L. This hydrogen powered a PEM fuel cell, achieving a maximum efficiency of 45.2% under an LED lamp load. This modification highlights potential improvements in electrolyzer performance for clean energy applications.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Jurnal Permadi : Perancangan, Manufaktur, Material dan Energi
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.