Abstract

IntroductionThe most common cause of failure in total hip arthroplasty (THA) is aseptic loosening. Uncemented cup migration analysis by EBRA (Einzel-Bild-Roentgen-Analyse) has shown to be a good predictive indicator for early implant failure if the cup migrates more than 1 milimeter (mm) within the first 2 years after surgery. In this study, we investigated the migration behaviour of an uncemented press-fit cup after 2 years follow-up.Materials and methodsApplying a retrospective study design, we reviewed all consecutive patients who received an uncemented press-fit cup at our Department between 2013 and 2018. A total of 484 patients were identified. We reviewed medical histories and performed radiological measurements using EBRA-Cup software. EBRA measurements and statistical investigations were performed by two independent investigators.ResultsA total of 165 cups in 159 patients (female: 90; male: 69) met our inclusion criteria. Mean age at surgery was 66.7 (range 18.4–90.5) years. EBRA migration analysis showed a mean total migration of 0.7 mm (range 0.0–6.3) over our follow-up period of 2 years. Of the investigated cups, 53.2% showed less than 1 mm migration in the investigated follow-up period.ConclusionIn conclusion, the Pinnacle cup used in our study provides low mean migration at final follow-up. Based on the assumption of secondary stabilization, good long-term outcome of the Pinnacle cup can be expected.Trial registration number and date of registrationNumber: 20181024-1875; Date: 2018-09-20

Highlights

  • The most common cause of failure in total hip arthroplasty (THA) is aseptic loosening

  • Published studies of uncemented cup migration investigated by means of EBRA (Einzel-Bild-Roentgen-Analyse) have shown this migration to be a good predictive indicator and threshold for later aseptic loosening [5,6,7,8]

  • A total of 484 Pinnacle cups were implanted as part of a primary THA

Read more

Summary

Introduction

The most common cause of failure in total hip arthroplasty (THA) is aseptic loosening. Uncemented cup migration analysis by EBRA (Einzel-Bild-Roentgen-Analyse) has shown to be a good predictive indicator for early implant failure if the cup migrates more than 1 milimeter (mm) within the first 2 years after surgery. Published studies of uncemented cup migration investigated by means of EBRA (Einzel-Bild-Roentgen-Analyse) have shown this migration to be a good predictive indicator and threshold for later aseptic loosening [5,6,7,8]. EBRA is a computer-assisted method for measuring the migration of acetabular cups using standard anterior–posterior (ap) pelvic radiographs without requiring additional means at exposure (e.g. ball markers) [9] It has proven accuracy and sensitivity in detecting migration of more than 1 mm as compared to RSA (Roentgen stereophotogrammetric analysis) [10,11,12]. The method used is chosen by the surgeon and subject to patient age and bone quality

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.