Abstract

Two methods were used to measure muscle tone in patients with decerebrate rigidity. In the first method forces of square waveform were applied and the calculated compliance of the joint was used as an index of rigidity. Oscillatory transients were seen at the same frequency as the physiological tremor. The range of normal variation in compliance was large and the values measured in the patients flucuated markedly which limited the value of this index. In the second method, where forces of sinusoidal waveform were employed, the resonant frequency of the joint was measured and used as an index of rigidity. This index proved reliable and reproducible.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.